PSI MEMBRANE® Pro-Base Specialty Alkali Resistant Membrane incorporating innovative Thin Film Nanocomposite (TFN) alkali-resistant membrane sheets and unique alkali-resistant materials. They have anti-fouling, high flux, high pressure resistance, and extreme alkali resistance properties.They can achieve concentration of cellulose, hemicellulose, papermaking fibers, and other compounds in alkaline solutions such as sodium hydroxide below 20% and potassium hydroxide below 10%, and can also be used for alkali purification and recovery. They can maintain high flux and stable operation for more than 12 months in strong alkali environments.

 

Product Parameter

Product Stabilized Salt Rejection(%) Permeate Flow Rate GPD(m³/d) Active Area Ft² (m²) Feed Spacer Thickness(mil)
Pro-Base-NF98-8040 98 13000 (49.2) 400 (37.2) 34
Pro-Base-NF96-8040 96 19500 (73.8) 400 (37.2) 34
Pro-Base-NF92-8040 92 24000 (91.0) 400 (37.2) 34
Pro-Base-NF80-8040 80 26000 (98.4) 400 (37.2) 34
Pro-Base-NF35-8040 35 39000 (147.6) 400 (37.2) 34
1.Permeate flow rate and stabilized salt rejection were based on the following standard test conditions: 2000 ppm MgSO4, 580 psi (4.01 MPa), 77 ℉ (25 ℃), and 15% recovery;
2. The variation range of permeate flow rate is +/-15%.

 

Operating Condition

Maximum Operating Temperature 60℃
Maximum Operating Pressure 1200 psi (83 bar)
Maximum Pressure Drop 1 bar
Continuous Operating pH Range 3-14
Cleaning pH Range 2-14
The largest water SDl15 5
Maximum influent turbidity 1 NTU
Maximum residual chlorine concentration of influent <0.1 ppm